Quick answers at the bench: read resistor, capacitor and inductor markings, work out series and parallel resistance, check cable voltage drop, and estimate how long a drive's DC bus takes to discharge. Everything runs in your browser, nothing is sent anywhere.
Type the code printed on the part. Understands 3-digit (472), 4-digit (1002), R / K / M decimal (4R7, 4K7) and EIA-96 (01C) markings.
The tolerance shown is what that marking style normally means, not a guarantee. Check the datasheet for critical parts, and measure in circuit only after isolating.
Pick the number of bands, then the colour of each band starting from the end with the bands closest together.
Understands 3-digit codes (104), an optional tolerance letter (104K), and p / n / u notation (4n7, 100n, 2u2, 4p7).
Voltage codes vary between manufacturers, so treat the voltage as a hint and check the datasheet. Many small ceramic capacitors carry no marking at all, so measure those with a capacitance meter.
First two digits are the value, the third digit is the number of zeros, and the result is in picofarads.
STARTING BUS VOLTAGE (V DC)
Supply buttons use the peak of the AC supply (RMS × 1.414). The real bus can sit higher with a high supply or regenerative load, so enter a measured value when you have one. Total capacitance = each × parallel ÷ series.
Model: V = V₀ · e^(−t / RC). Real drives often discharge through their own power supply as well, which changes the curve, and discharge slows to a crawl at low voltage.
Estimate the voltage lost along a cable run, and the smallest cable size that keeps the drop inside your limit.
Length is the one-way run from the supply to the load. The calculation already counts the return conductor (single-phase and DC) or all three phases. Common UK working limits are 3% for lighting and 5% for other circuits, but check the current edition of the wiring regulations and the equipment's own voltage tolerance.
Resistive drop only, using standard copper and aluminium resistivity. Real stranded cable is usually a few percent higher, and reactance matters on large cables at low power factor, so use the manufacturer's mV/A/m tables for compliance work. Voltage drop is one check among several: current rating, grouping, ambient temperature and the protective device must be checked separately, and motor starting current causes a much larger short-term drop.
Type your values separated by spaces or commas, for example 4k7 10k 2k2 or 4R7, 100, 1M2. k = kilo, M = mega, R = ohms, and the letter can sit in place of the decimal point (4k7 = 4.7 kΩ).
You have one resistor and need a particular total. This uses the series or parallel setting on the left.
Standard values are from the E24 (5%) and E96 (1%) series. The tolerance of the parts you use adds to any error shown here.
Axial moulded inductors use the resistor colour code, with the answer in microhenries (µH). Read from the end with the bands closer together. Some inductors have a wider first band to tell them apart from resistors. If you can't tell, measure the part with an LCR meter.
Black or no tolerance band means ±20%. Precision parts may use other tolerance colours, so confirm against the datasheet.
Chip and moulded inductors are often marked in microhenries. Understands 3-digit codes (101), an optional tolerance letter (221K), R as a decimal point in µH (4R7), and N for nanohenries (4N7).